2 New Zero Hour JGQ/2 Ariel Angi Packaged CNG Compressors with Warranty

$750,000 (USD)

Available quantity:2

Description

JGQ/2

With Warranty


Compressor 2 like this

Compressor type……………….

Make/Model……………………. Ariel

Capacity @ rated psig inlet ……. 1282 SCFM @ 675 PSIG

Electrical Rating………………… Class 1 Division 2 Group D

Operating Speed……………….. 1800 RPM

Ambient Temperature Range….. -20°F to 105°F

Inlet Pressure Range……………. 210 PSIG to 675 PSIG

Maximum Discharge Pressure… 4500 PSIG

Stroke……………………………. 3.0 Inch

Number of Stages………………. 3

Number of Cylinders……………. 3

Pressure Relief Valves…………. Per stage on the discharge piping

Oil Sump Capacity ……………… 2-1/2 Gallons

Oil………………………………… ANGI GLY-100

Drive Method……………………. Direct drive through rigid Coupling

Compressor Lubrication

 Frame………………………..

 Cylinders and Packing………

Driver

Prime Mover…………………….. TEFC AC Electric Motor

Make / Model…………………… Baldor

Motor Specification

 Rated Speed…………………. 1800 RPM

 Rated Voltage………………… 460 VAC

 Rated Horsepower…………… 300 HP

 Service Factor……………….. 1.15

 Classification…………………. CL1 Div2

 Motor Starting Method………. Off-skid Soft Starter

Cooling Fan Motor

Prime Mover…………………….. TEFC AC Electric Motor

Make / Model…………………… Baldor

Motor Specification

 Rated Speed…………………. 1800 RPM

 Rated Voltage……………….. 460 VAC

 Rated Horsepower………….. 15 HP

 Service Factor………………. 1.15

 Classification………………… CL1 Div2

 Motor Starting Method………. Full Voltage Starter

Heavy-Duty, Balanced, Opposed, Lubricated, Reciprocating

Compressor

Frame mount, chain driven oil pump, with regulator, provides

lubrication to the running gear. Oiling system includes electric

driven pre-lube pump, oil cooler, thermostatic valve,

replaceable filter, strainer and sight gauge.

Forced lubrication divider block assembly provides set amounts

of oil to pistons and packing. The circuit includes rupture disc,

flow detection and a divider block for each point. The system is

supplied by the frame lubrication system.

60316 Tech Spec.xlsm 1 of 2

SPECIFICATION (Cont.)

Package

Dimensions

 Length………………………… 12'0" Long

 Width…………………………. 8'6" Wide

 Height………………………… 8'5" High

 Weight……………………….. Approx. 15,000 lbs.

Gas Cooling

 Inlet Gas Temp. (Design)…… 60°F

 Gas Spec. Gravity (Design)… 0.59

 Gas Cooling Approach Temp 20°F Interstage, 15°F final

 Method……………………….. Forced air fan cooling

 Inter-stage Cooling………….. Yes

 After Cooling………………… Yes

Gas Filtration

 Particulate Filters……………. Yes – Inlet filtration

 Coalescing Filters…………… Yes – Inter-stage and discharge filtration

 Captive Recovery Tank……… Provided - To allow periodic

unloading of each compressor

stage and to allow unloaded

re-start

Site Electrical Requirements….. 460 VAC / 60 Hz / 3 Phase

 Drive Motor(s)……………….. 361 FLA 2 Motor(s)

 Cooling Fan Motor(s)………. 21 FLA 2 Motor(s)

 Prelube Pump Motor(s)……. 1.1 FLA 2 Motor(s)

 Control power……………….. 20.0 Amps

Total Package Power req'd……. 876.5 Amps (inc. 125% FLA of Largest Drive Motor)

Enclosure

 Type…………………………..

 Enclosure Heater…………… Lube Oil Heater 1500W-120V, Enclosure Heater, Heat Trace

 Sound Level…………………. 78 dBa @ 10'

 Gas Detection………………. Std one IR detector per unit


Compressor one like this

Compressor type……………….

Make/Model……………………. Ariel

Capacity @ rated psig inlet ……. 1246 SCFM @ 750 PSIG

Electrical Rating………………… Class 1 Division 2 Group D

Operating Speed……………….. 1800 RPM

Ambient Temperature Range….. -20°F to 105°F

Inlet Pressure Range……………. 300 PSIG to 750 PSIG

Maximum Discharge Pressure… 4500 PSIG

Stroke……………………………. 3.0 Inch

Number of Stages………………. 3

Number of Cylinders……………. 3

Pressure Relief Valves…………. Per stage on the discharge piping

Oil Sump Capacity ……………… 2-1/2 Gallons

Oil………………………………… ANGI GLY-100

Drive Method……………………. Direct drive through rigid Coupling

Compressor Lubrication

 Frame………………………..

 Cylinders and Packing………

Driver

Prime Mover…………………….. TEFC AC Electric Motor

Make / Model…………………… Baldor

Motor Specification

 Rated Speed…………………. 1800 RPM

 Rated Voltage………………… 460 VAC

 Rated Horsepower…………… 200 HP

 Service Factor……………….. 1.15

 Classification…………………. CL1 Div2

 Motor Starting Method………. Off-skid Soft Starter

Cooling Fan Motor

Prime Mover…………………….. TEFC AC Electric Motor

Make / Model…………………… Baldor

Motor Specification

 Rated Speed…………………. 1800 RPM

 Rated Voltage……………….. 460 VAC

 Rated Horsepower………….. 15 HP

 Service Factor………………. 1.15

 Classification………………… CL1 Div2

 Motor Starting Method………. Full Voltage Starter

Heavy-Duty, Balanced, Opposed, Lubricated, Reciprocating

Compressor

Frame mount, chain driven oil pump, with regulator, provides

lubrication to the running gear. Oiling system includes electric

driven pre-lube pump, oil cooler, thermostatic valve,

replaceable filter, strainer and sight gauge.

Forced lubrication divider block assembly provides set amounts

of oil to pistons and packing. The circuit includes rupture disc,

flow detection and a divider block for each point. The system is

supplied by the frame lubrication system.

60341 Tech Spec.xlsm 1 of 2

SPECIFICATION (Cont.)

Package

Dimensions

 Length………………………… 12'0" Long

 Width…………………………. 8'6" Wide

 Height………………………… 8'5" High

 Weight……………………….. Approx. 15,000 lbs.

Gas Cooling

 Inlet Gas Temp. (Design)…… 60°F

 Gas Spec. Gravity (Design)… 0.59

 Gas Cooling Approach Temp 20°F Interstage, 15°F final

 Method……………………….. Forced air fan cooling

 Inter-stage Cooling………….. Yes

 After Cooling………………… Yes

Gas Filtration

 Particulate Filters……………. Yes – Inlet filtration

 Coalescing Filters…………… Yes – Inter-stage and discharge filtration

 Captive Recovery Tank……… Provided - To allow periodic

unloading of each compressor

stage and to allow unloaded

re-start

Site Electrical Requirements….. 460 VAC / 60 Hz / 3 Phase

 Drive Motor(s)……………….. 240 FLA 1 Motor(s)

 Cooling Fan Motor(s)………. 21 FLA 1 Motor(s)

 Prelube Pump Motor(s)……. 1.1 FLA 1 Motor(s)

 Control power……………….. 10.0 Amps

Total Package Power req'd……. 332.1 Amps (inc. 125% FLA of Largest Drive Motor)

Enclosure

 Type…………………………..

 Enclosure Heater…………… Lube Oil Heater 1500W-120V, Enclosure Heater, Heat Trace

 Sound Level…………………. 78 dBa @ 10'

 Gas Detection………………. Std one IR detector per unit

Powder-coated sheet metal enclosure with access doors and

removable panels.

60341 Tech Spec.xlsm 2 of 

--


Specifications

ManufacturerAriel
ModelJGQ/2
Year2024
ConditionNew
Stock Number00081