Xebex STR18NGX1.5 Dryer

Xebex STR18NGX1.5 Dryer

orCall +1 773-960-5642

Description

Pristine looking Regen unit used for 2 years. 454 CFM per minute.

5.3 460-VAC DRYER

STR18NGX

INSTALLATION SITE

CLASSIFICATION CLASS I, DIVISION 2, GROUP D

ASME VESSEL CODE

CONSTRUCTION UW12c

SYSTEM RELIEF VALVE

SETTING 150 psig (1,034 kPag) standard, higher pressure available

OPERATING PRESSURE 5 – 150 psig (34 – 1034 kPag)

OPERATING FLOW 420 SCFM @ 10 PSIG

INLET GAS WATER

CONTENT 7 #H2O/MMSCF

OUTLET DEW POINT -76°F (-60°C)

INLET GAS

TEMPERATURE -10°F to +100°F (-23°C to +38°C)

CONNECTION SIZE –

CLASS 150# RF ANSI

B16.5

1.5-in

flange

2-in flange 2-in flange 3-in flange 2-in flange 3-in flange

DRYER DESIGN

VOLTAGE 460 Vac/3-ph/60 Hz

MIN. CURRENT DRAW

ON 460 Vac 18A 18A 22A 22A 22A 22A

DESICCANT TYPE M001-

QTY IN POUNDS/

KILOGRAMS

330/150

BLOWER MOTOR – 2 hp,

1800 rpm, Class 1 Div 1

Grp D

460 Vac: 2.8A full load current (FLC) overload setting

COOLER MOTOR – 0.225

hp, 1800 rpm, Class 1 Div 2

Grp D type TEFC

460 Vac: 0.6A FLC overload setting

HEATER SIZE ( MINIMUM) 12kW 12kW 15kW 15kW 15kW 15kW

REGEN HEAT TIMER

(PLC) Set at 5 hours max.

REGEN COOL TIMER

(PLC) Set at 5 hours max.

TSH-1A ALARM SETTING Heater sheath: set at 720°F (382°C)

TSH-2 ALARM SETTING Heater outlet: set at 500°F (260°C)

TSH-3 CONTROL

SETTING Heater outlet: set at 425°F (218°C)

TSl-3 ALARM SETTING Heater outlet: set at 250°F (121°C)

TSH-4 CONTROL SET Cooler inlet, terminate heating: set 200°F (93°C)

TSL-4 CONTROL SET Cooler inlet, terminate cooling: set 120°F (49°C)

TSH-5 ALARM SETTING Cooler outlet: set 135°F (57°C)

PI-1 PRESS INDICATOR 0 – 200 psig for 150 psig systems (0 – 1379 kPag for 1034 kPag systems

Specifications

ManufacturerXebec
ModelStr18NGX1.5
Year2010
ConditionUsed
Serial Number22942